Skip to main content

Processing Data from Observation to Archival

This is a more simplified version of some of the pages David made. It details the pipeline used to turn voltages to filter-banks, clean and search them before archival on DIAS or Archie. 

Disk Space 

There is a lack of disk space locally in Birr. By default the observing is stored in /mnt/ucc1_recording2/data/observations/. This  is one of the reasons that UCC1 shouldn't be used during observations. Keep an eye on the data rates throughout observation, if there is no space then there is no observations. This can be done through the terminal using df -h . Also there is a script setup to email the observing mailing list when the space on the disk drops below 20%.

The data rates for the observations are as follows, this is a good way to see if you have enough space left for the remaining observation time. 

 

Observation 
Data Rate (GB/hr) 
BF-ed HBT 
~550
KBT (Sun) 
~700

This means that for a given full day of observation, about 14 TB is needed, KBT dependent